Intergas boilers

Intergas boiler models and common faults.

Which Intergas boilers we work on, the model names you may find on the label, and the faults we are most often asked about. Heating People arranges diagnostic visits in East London and surrounding areas.

Book a boiler diagnostic

Get a Repair Quote from Your Photos

Call free 0800 118 2128

Engineer carrying a tool bag at the front door of a home, greeted by the homeowner

Intergas ranges we work on

Current ranges: Combi Compact ECO RF, Combi Compact HRE, Rapid, Compact SRE HB, Compact HRE OV.

Older ranges we still see: Combi Compact HRE 24/18, 28/24 and 36/30.

Model names you may find on the label

Combi Compact ECO RF, Combi Compact HRE 24/18, 28/24 and 36/30, Rapid, Compact SRE HB, Compact HRE OV.

This is a guide, not a complete list. The model name is usually on the front of the boiler or on its data label, and a clear photo of it helps us prepare. If your model is not listed, send it to us and we will confirm before you book. Range and model names were compiled from manufacturer and trade sources on 6 November 2026; names and availability change, and parts for older models cannot be guaranteed.

Faults we are asked about on Intergas boilers

Faults common to most gas boilers, Intergas included

  • Low or dropping pressure. A leak, recently bled radiators or a faulty pressure relief valve are the usual causes. A sudden drop suggests a leak; a gradual drop may only need repressurising.
  • Hot water but no heating, or heating but no hot water. On a combi, a stuck diverter valve is a frequent cause of lost hot water. Timer, thermostat and settings (for example after a power cut or clock change) are worth checking first.
  • Lockout in cold weather. A frozen or blocked condensate pipe, especially an external one, shuts many condensing boilers down. Low pressure, ignition or flame detection, a fan fault or a circuit board fault can also cause a lockout.
  • Kettling, whistling, gurgling or banging. Limescale or sludge on the heat exchanger causes kettling. Air in the system, low pressure or restricted flow cause the other noises.
  • Radiators cold at the top or bottom. Cold at the top usually means trapped air; cold at the bottom usually means sludge.
  • Water leaking from the boiler. Worn seals, a pressure relief valve discharging or corroded parts are typical. An engineer needs to open the boiler to diagnose it.
  • Switching itself off. Low pressure, a thermostat problem, a pump that is not circulating, closed valves or air in the system can all make a boiler cut out.

Trade guides do not tie these faults to particular Intergas models, so treat the lists as a guide to what a symptom can mean, not a diagnosis. A displayed code is useful evidence, not a confirmed failed component: the engineer assesses the boiler and the connected heating system before recommending the next step. Fault information was compiled from manufacturer and trade guides (including Which?, Checkatrade, HomeServe, Heatable and Boiler Guide) on 6 November 2026.

Next steps for your Intergas boiler

The £92.50 covers up to 45 minutes to investigate the fault. We aim to get your boiler working during the visit where possible. The fee is for the diagnostic visit and is payable regardless of the outcome. Any further repair work is agreed separately. What happens at the visit. At the end of the visit we’ll explain what we found, whether the boiler is working, whether any fix is temporary, and what we recommend next. If we can carry out the next stage, we’ll explain the scope and agree any additional cost with you before proceeding.